SpectraSim Documentation
Parameter · 04 Material

Ambient air temperature

material.ambient.temperature_C Unit: °C Step 04 · Material

The temperature of the air outside the muffler, in the Material step's Ambient air panel together with the atmospheric pressure and the relative humidity. It is used twice: the outlets radiate into this air (insertion loss, Insertion loss: radiation into the ambient air), and it sets the atmospheric attenuation coefficient α\alpha of the radiated SPL's path from the outlet to the microphone (ISO 9613-1). It is not the gas temperature inside the muffler (Temperature).

Last updated

Theory

Sound in air is absorbed by two mechanisms:

  • viscosity and heat conduction (classical and rotational absorption);
  • vibrational relaxation of oxygen and nitrogen molecules, whose relaxation frequencies depend on the water-vapour content and the temperature.

The program computes the pure-tone attenuation coefficient of ISO 9613-1, equation (1), with the relaxation frequencies of equations (2) and (3). At the default distance of 0.5 m the absorption is small (hundredths of a dB at a few kHz); it becomes significant at large distances and high frequencies.

Equations

α=8.686f2[1.84×10−11(papr)−1(TT0)1/2+(TT0)−5/2(0.01275 e−2239.1/TfrO+f2/frO+0.1068 e−3352.0/TfrN+f2/frN)]\alpha = 8.686 f^2\left[1.84\times10^{-11}\left(\frac{p_a}{p_r}\right)^{-1}\left(\frac{T}{T_0}\right)^{1/2} + \left(\frac{T}{T_0}\right)^{-5/2}\left(\frac{0.01275\,e^{-2239.1/T}}{f_{rO} + f^2/f_{rO}} + \frac{0.1068\,e^{-3352.0/T}}{f_{rN} + f^2/f_{rN}}\right)\right]
(1)
frO=papr(24+4.04×104 h 0.02+h0.391+h)f_{rO} = \frac{p_a}{p_r}\left(24 + 4.04\times10^{4}\,h\,\frac{0.02 + h}{0.391 + h}\right)
(2)
frN=papr(TT0)−1/2(9+280 h exp⁡ ⁣[−4.170((TT0)−1/3−1)])f_{rN} = \frac{p_a}{p_r}\left(\frac{T}{T_0}\right)^{-1/2}\left(9 + 280\,h\,\exp\!\left[-4.170\left(\left(\frac{T}{T_0}\right)^{-1/3} - 1\right)\right]\right)
(3)
wheremeaningunit
α\alphaAttenuation coefficientdB/m
ffFrequencyHz
pap_aAmbient pressurekPa
prp_rReference pressure, 101.325kPa
TTAir temperature (this setting, in kelvin)K
T0T_0Reference temperature, 293.15K
frO,frNf_{rO}, f_{rN}Relaxation frequencies of oxygen and nitrogenHz
hhMolar concentration of water vapour (Relative humidity)%

Default and rule

Default
25 °CMeasured
Rule

25 °C.

Source

The equations are those of ISO 9613-1, eqs. (3)-(5). The implementation was verified against a tabulation of the attenuation coefficients (relative humidity 10-100 %, the temperatures of the input range, the tabulated frequencies): 1789 of 1848 values agree within 0.5 % (median 0.07 %). The remaining 59 differ because of transcription errors in the tabulation (decade or digit errors, e.g. 0.897 where 0.0897 is correct at 20 °C / 63 Hz / 70 %). The input range 15-40 °C is the program's.

Valid range -40 to 60 °C (radiated SPL: 15 to 40 °C)

Values

-40 to 60 °C, the range of the insertion loss's outside air.

Radiated SPL

The radiated SPL accepts 15 to 40 °C only: a run that computes it is refused outside that range.