material.ambient.relative_humidity_pct Unit: % Step 04 · Material

Of the air OUTSIDE the muffler (Material step, Ambient air). It is used only for the air absorption of the radiated SPL. It is not the humidity of the gas inside the muffler (Relative humidity, Fluid: Humid air).

The relative humidity of the outside air at the measurement position. The water-vapour content sets the relaxation frequencies of oxygen and nitrogen, and through them the air absorption between outlet and microphone.

Last updated

Theory

The attenuation coefficient (Ambient air temperature) requires the molar concentration of water vapour hh. The program derives it from the relative humidity, the saturation vapour pressure over liquid water at the air temperature, and the ambient pressure, equations (1) and (2) (ISO 9613-1 Annex B).

The absorption does not vary monotonically with humidity: the humidity shifts the relaxation frequencies, and with them the frequency range in which each relaxation process absorbs most.

Equations

h=hrel psat/prpa/prh = h_{rel}\,\frac{p_{sat}/p_r}{p_a/p_r}
(1)
psatpr=10 C,C=−6.8346(T01T)1.261+4.6151\frac{p_{sat}}{p_r} = 10^{\,C}, \qquad C = -6.8346\left(\frac{T_{01}}{T}\right)^{1.261} + 4.6151
(2)
wheremeaningunit
hhMolar concentration of water vapour%
hrelh_{rel}Relative humidity (this setting)%
psatp_{sat}Saturation vapour pressurekPa
pap_aAmbient pressurekPa
prp_rReference pressure, 101.325kPa
TTAir temperatureK
T01T_{01}Triple-point isotherm temperature, 273.16K

Default and rule

Default
70 %
Rule

70 %. This is the program's default, chosen within the tabulated range of 10-100 %; it is not taken from a standard.

Source

ISO 9613-1 Annex B. The conversion is verified through the attenuation coefficients against tabulated values (see Ambient air temperature).

Valid range 10 to 100 %

Values

10 to 100 %.