SpectraSim Documentation
Parameter · 07 Run Settings

Sound power through sections

acoustics.extra_results.sections_enabled Step 07 · Run Settings

The net sound power through planes across the model at every swept frequency, computed during the sweep.

Last updated

Theory

A section is a plane normal to x, y or z at a percentage of the model's extent. It is sampled on a regular grid inside the gas, where the active intensity is summed. The part of a plane inside a packing is left out and reported. Details: Additional acoustic results: receivers, section power, dissipation, flow effect. For one frequency, the Results step's acoustic field plot gives the same power on any section without a new run.

Equations

W=∑qh2 12Re(pq vn,q∗)W = \sum_q h^2\, \tfrac12 \mathrm{Re}\left(p_q\, v_{n,q}^*\right)
(1)
wheremeaningunit
WWNet power through the plane, positive along its normalW
wqw_qArea weight: exact gas area of the plane over the number of samples (spacing 1/90 of the longest size)m²
pq,vn,qp_q, v_{n,q}Pressure and normal particle velocity at a samplePa, m/s

Default and rule

Default
off
Rule

Off.

Valid range on | off

Cost

About 2 % of the sweep.

Packing

The area inside a packing is not counted.